Product family
System scaffold
The cup-jointed frame of standards, ledgers and transoms you build access scaffold from.
- Cuplock SystemStandards with cups every 0.5 m, locked to ledgers and transoms.
Product family
Temporary works must hold firm from start to finish. GV supplies the steel components that make it possible: cuplock standards and ledgers for system scaffold, steel planks for working decks, base jacks and heavy U-head jacks to level towers, adjustable props with their pins, nuts and threaded tubes for formwork, and trench struts to hold excavations open. We source each part to the size series and standard your project requires.
Explore scaffolding & shoring systems ↗
Six families
Organized by type. Know a product by another name? Find it in the trade-names list.

Product family
The cup-jointed frame of standards, ledgers and transoms you build access scaffold from.

Product family
The steel boards you lay across each lift to stand and work on.

Product family
Threaded jacks that level a scaffold at the foot and carry beams at the top of a tower.

Product family
Adjustable steel props in sizes #0 to #4, set to height under formwork or a slab.

Product family
The pin, nut and threaded sleeve you replace to keep props working.

Product family
Telescopic struts you set across an excavation to hold its sides.
Where it's used
Building facades, plant rooms, tanks and stair towers all need safe access at height while the work goes on. System scaffold goes up fast in regular bays and takes a full working deck at each lift. Cuplock System, Planks and Screw Jack with Base Plate & Wing Nut cover it.
Wet concrete has to be carried until it can carry itself, and the slab above often needs back-propping while the next floor is poured. Props set to height under the formwork do that job, floor by floor. Props, Threaded Tube, Prop Nut and G Pin cover it.
Bridge decks, transfer slabs and high ceilings need taller, heavier support than a single prop can give. Towers built with adjustable jacks top and bottom carry the beams that hold the formwork. Hi-Load Screw Jack with Wing Nut, Screw Jack with Base Plate & Wing Nut and Cuplock System cover it.
Drainage runs, utility trenches and pit excavations must be kept open while people work inside them. Struts set across the trench hold its sides back against the ground. Trench Struts and G Pin cover it.
Hire companies and contractors keep large fleets of props running, and pins go missing and nuts wear. Spare parts made to the same size series keep every prop in use. G Pin, Prop Nut and Threaded Tube cover it.
Scaffolding and shoring systems
CUPLOCK
Standards carry cups every half meter, and each ledger and transom locks into a cup node with no loose fittings. Bays of 0.6 to 3.0 m go up in regular lifts on base jacks.

Diameter: 2 in (N.B.) / 48.3 mm (O.D.), 3.2 or 4.0 mm wall · Length: 3-12 ft / 1-4 m; verticals in 0.5 m steps
Specifications
Diameter: 1-1/4, 1-1/2 in (N.B.) / 33.7, 38, 38.1 mm (O.D.); 26-48 mm to order · Length: 24-36 in / 600-900 mm
Specifications
Width: 9, 10, 12 in / 200-500 mm; 225, 230, 238, 250, 300, 320 mm common · Depth: 38, 50, 57, 63, 76 mm
SpecificationsWORKING DECKS
Steel boards laid side by side across the transoms make the deck at each lift, on system scaffold or tube-and-fitting scaffold.

Width: 9, 10, 12 in / 200-500 mm; 225, 230, 238, 250, 300, 320 mm common · Depth: 38, 50, 57, 63, 76 mm
Specifications
Diameter: 1-1/4, 1-1/2 in (N.B.) / 33.7, 38, 38.1 mm (O.D.); 26-48 mm to order · Length: 24-36 in / 600-900 mm
SpecificationsPROPS
An inner tube slides inside a threaded outer tube. A pin sets the height in steps, and a nut on the thread takes it the rest of the way.

Size: #0, #1, #2, #3, #4 · Height: #0: 1.1-1.8 m; #1: 1.75-3.12 m; #2: 2.0-3.4 m; #3: 2.59-3.96 m; #4: 3.2-4.87 m
Specifications
Size: #0, #1, #2, #3, #4 · Tube: 60.3 mm O.D., 3.6 mm wall
Specifications
Size: #0, #1, #2, #3, #4 · Thread: 4 TPI, to suit 60.3 mm threaded tubes
SpecificationsFALSEWORK
Towers stand on base jacks and carry beams in U-heads or fork heads at the top, so the formwork sits at exactly the right level.

Diameter: 1-1/4, 1-1/2 in (N.B.) / 48.3, 60.3 mm (O.D.) · Length: 30-120 in / 760 mm-3 m
Specifications
Diameter: 1-1/4, 1-1/2 in (N.B.) / 33.7, 38, 38.1 mm (O.D.); 26-48 mm to order · Length: 24-36 in / 600-900 mm
Specifications
Diameter: 2 in (N.B.) / 48.3 mm (O.D.), 3.2 or 4.0 mm wall · Length: 3-12 ft / 1-4 m; verticals in 0.5 m steps
SpecificationsTRENCH SHORING
Struts span the excavation between walings or trench sheets on each side, extended to fit and locked with a pin and screw.
How GV sources this
You define the specification, drawing, or standard. We work with your engineering requirements—ASTM grades, dimensions, finishes, certifications.
We audit and certify manufacturing partners in India. First-article inspection and approval. Blanket orders or scheduled releases as you need.
Pre-shipment inspection and third-party verification on request. Mill test reports, coating certificates, dimensional reports—documentation packs in every container.
Consolidated shipments to US ports and job sites. Landed-cost pricing in USD. Single point of contact in Katy, Texas for order management and support.
Questions answered
Our team is ready to help you find the right products.